1. Clear Memory Crash
Step 1. Press
6 times on the F2 key (SY711) or the 0 key (SY715).
An asterisk will appear for each time that this key is
pressed.
Step 2. Press
once on the F4 key (SY711) or the ENTER key (SY715).
Step 3. Press
3 times on the OUT key.
Step 4. Press
twice on the F2 key.
Step 5. Press
3 times on the OUT key.
The message CLEAR
MEMORY? will appear on the display.
Step 6. Press
once on the F2 key for confirmation.
The message MEMORY
CLEARED will appear on the display.
If you make an error
during steps 3 through 6, the terminal will revert to the state just prior to
step 3.
If you find yourself unable to complete this operation, exit the
technician mode by pressing the IN key
until F2/OUT appears on the
display, then press the OUT key.
Then begin again from step 1.
Step 7. Please re-program the terminal
from Software.
2. Create Memory Crash
Step 1. Unplug the terminal and make sure that it is
off. The backup battery automatically supplies power for approximately 15
seconds.
Step 2. Unscrew and remove the front panel.
Step 3. Move the J4 jumper (1) from the BT position to Z.
Step 4. Plug the terminal back into a power source and
make sure that MEM CRASH appears
in the terminal display.
Step 5. Unplug the terminal and return the J4 jumper
to its original position (BT).
Step 6. Plug the terminal back into a power source and
make sure that MEM CRASH reappears
in the terminal display.