Secure IO Relay does not open for XPass on Biostar
If you’re using Secure Relays with Xpass and the relay doesn’t
open despite being defined correctly in Biostar as the Secure IO Relay (not the
internal Xpass) then check your Firmware version.
FW 1.2.3 doesn’t work and should be replaced with FW1.2.4 (attached)
I have already put the file on the 6 farms who have Biostar
installed. After defining your device go to the device properties and click
Upgrade Firmware.
You will be given a choice of 2 select the one for V1.2.4
Related Articles
Finding Biostar Device Mac address using Serial Number
Finding Biostar Device Mac address using Serial Number. If you would like to find the device’s IP based on the MAC address you can follow the steps below. 1.Check your device ID written on the device label on the back of the device. 2.Change the ...
Finding the MAC Address of a Suprema Device
There may be several reasons why you would like to know the MAC address of a Suprema device: You do not have a DHCP server and need to give IP address based on a MAC address You do not know the IP of your device and are having difficulty searching it ...
Finding Biostar Device Mac address using Serial Number
Finding Biostar Device Mac address using Serial Number. If you would like to find the device’s IP based on the MAC address you can follow the steps below. 1.Check your device ID written on the device label on the back of the device. 2.Change the ...
Access Control Event Types by Device
Apart from generic event types, please see below specific Event types by device that we currently support within Synergy Workforce I.e. you can enable them under Event Types so that they are visible within Guard Screen SALTO: 100 SALTO - Open ...
ER2 - New Suprema Devices Maintenance Menu
There is a new menu ‘Maintenance’ > ‘Biostar Devices’ that allows full control over deleting and syncing persons and access control data to the Suprema biostar devices. The screen has two selection boxes, one for persons and the other for devices. ...