ER2 - Upgrading EduReg after SIMS version release

ER2 - Upgrading EduReg after SIMS version release

Upgrading EduReg after SIMS version release


how to upgrade the EduReg Installation following a SIMS version release.

Following a SIMS version release the version of the SIMS client on the EduReg server will need to be checked to ensure that the client has also been upgraded to match the SIMS server before proceeding with the upgrade detailed below.

1. Navigate to the SIMS client folder on the EduReg server which is usually located C:\ProgramFiles (86)\SIMS\SIMS.net\


         

         

SIMS version update utillity

Utillity to update the SIMS version in all the config files required.

Locate the following file in the EduReg2\Utilities folder

SIMSVersionUtility.exe



Run SIMSVersionUtility.exe

The current version will be shown in the field ‘Current SIMS Version’

Enter the new update version of SIMS in the field ‘New SIMS Version’


Click Update

Check the ‘Success’ pop up that all files have been updated


Once this has been done and all the files saved, restart the following windows services.
( not all dll.config files and services will be present on every system)

    AMPMservice

    CloseRegisterService

    SySyncService



    • Related Articles

    • ER2 Cashless Till Boot Failure

        EduReg2 – Technical Support Document  Cashless Till (Windows 10 model)  Symptom:  Till will not boot up on restart and shows the error ‘Your PC Ran into a problem and needs to restart. We’re just collecting some error info, and then we’ll restart ...
    • ER2 FireReport not Printing to a Printer

      Fire Report not printing to a physical printer If the FirereportPrinting Crashes: 1. This could be because the terminals that it is trying to open on Access control are not Access Control terminals or the SynDll.exe is not current 2. Add the ...
    • ER2 - Cashless - Product Purchase Limit

      Synel ER2 Cashless                                                                                                                          04/05/2019 New feature for product purchase limit. Applies to version 3.7.0.29052019 and above 1. Access ER2 ...
    • Secure IO Relay does not open for XPass on Biostar

      If you’re using Secure Relays with Xpass and the relay doesn’t open despite being defined correctly in Biostar as the Secure IO Relay (not the internal Xpass) then check your Firmware version. FW 1.2.3 doesn’t work and should be replaced with FW1.2.4 ...
    • ER2 - Cashless - Till Boot Failure

      EduReg2 – Technical Support Document Cashless Till (Windows 10 model) Symptom: Till will not boot up on restart and shows the error ‘Your PC Ran into a problem and needs to restart. We’re just collecting some error info, and then we’ll restart for ...